Stop module with damping ASM-620
For stopping and separating of one or more accumulated workpiece carriers on a defined workpiece carrier stop surface.
Particularly low profile. Ideally suited for stopping workpiece carriers WT 2/H in the Bosch Rexroth TS 2plus.
Technical data
DEVICE DESIGN
Stop module with adjustable air damping.
Particularly low building height
Basic housing made of hard anodized aluminum and stop plate made of hardened steel.
PRODUCT WEIGHT
ASM-620-EW-15-I: 4,9 kg
Pneumatic function
The stop modules ASM-620 are offered as single-acting variants (EW) For the EW-version there is only one air connection (P1) for lowering the stop module The air connection hole is located on the front of the stop module

EFFECTIVE PISTON AREAS
The forces are dependent on the pneumatic pressure, the piston
surface and the spring force.
During the respective working movements, the following piston
surfaces are subjected to compressed air:
Piston surface for lowering: 2513 mm²
Piston surface for extending the damping: 3927 mm²
SPRING FORCES
Spring force in raised position: F1 = 100 N
Spring force in lowered position: F2 = 250 N
TEMPERATURE RANGE
Standard version: -20°C to +80°C
OPERATING PRESSURE AND AIR CONSUMPTION
Operating pressure:
pmin = 4 bar
pmax = 8 bar
Compressed air quality:
ISO 8573-1 grade 4 or better
Size of the holes for air connection: G1/8
Cylinder volume for one cycle (lowering and extending the stop plate) : 140 cm³
The air consumption Q in “Norm litres” Nl can be calculated with these cylinder volumes and is specified in the operating manual
POSITION QUERY
In the standard version ASM-620-EW-15-I, the upper position and the lowered position can be queried using inductive sensors.
ADJUSTMENT OF DAMPING
The damping effect can be adjusted on the top of the device at the ASM-620 series by using a slotted screwdriver. The setting direction is marked on the device. The marks have the following meaning:
+ … increased damping effect
– … reduce the damping effect.
MAINTENANCE WORK
No maintenance work is required.
The area around the stop must be clean and free of dirt and chips to ensure precise positioning of the workpiece carrier.
SCOPE OF SUPPLY
The devices in standard configuration are supplied without accessories.
The accessories are freely selectable and adapt to the ambient conditions.
For variants with a three-digit number at the end of the type code, accessories are sometimes included in the scope of delivery.